Friday, February 28, 2014

Vista 15p ademco 6150rf 6160 programming

Vista 15P, Ademco 6150RF, 6160 programming


Hey Guys! I recently purchased an Ademco Vista-15P with a couple of wireless doors/windows contacts and motion sensor. In the package include an Ademco 6150FR keypad and someone told me that in order to program I would need to get the 6160 keypad witch I just got it. Now, I follow the programming from the 6160 by using *56 program code and then turn on the wireless keypad showing me the number 100 and then 1 fire and it counts up to 6. I don't know what is it that I am doing wrong but, I really need help. Have you set the addresses for both keypads? Look carefully at the instructions for the 6150Rf keypad, the procedure for setting the address is a little different from the ones for addressing the 6160. Yup!, is 24 but still showing numbers and not ready message. There's your problem: You need to set the 6160 to address 16, and the 6150rf to address 17 and activate address 17 in the system programming. On a vista 20p _there_is_no_keypad_24_. Well...I am only going to use the 6150RF keypad. The reason why I bought this 6160 is for programming purpose. Now, in programming number *24 is for RF House ID Code and that is set to 24 and I just don't know if is correct. On the actual display I have the following codes error: 100 check 1 fire check 02 check 03 check 04 check 05 check 06 check What I am trying to do is use this vista-15p system along with wireless devices only. My house is not pre-wire. I also notice that there is a red light in the back of the panel 6150RF and is on. I am telling you guys this system is driving me Thanks!. No, the RF ID code has nothing to do with the keypad address. Did you not read what was previously posted? What you are doing wrong, is failing to read your installation instructions. Just in case you don't have them: http://www.alarmsuperstore.com/ademc...ads/6150rf.pdf To activate address 17 once you go to system programming with [installer code] + 8 + 00 enter *190 10 then exit programming with *99 Once you set the keypad address in the keypad itself, you will be able to use _both keypads_ Your zones are showing open because you have neither resistors on the zone inputs, nor have you yet disabled the hardwire zones. Check 100 shows because you have no transmitters enrolled into the system yet. Thanks for your replay MrRonFL, it really helps me to figured it out. I made the programming as you recommend me and it works then, I follow the next step witch is setting up the 6150RF keypad by pressing 1 and 3 at the same time after programming. Then, I enter into the first option witch is 1 to setup the keypad address (witch I program to be 17) then, option 8 witch is the wireless key auto enroll with their respective serial number. Now, the high security mode witch is option 0 is off because the manual says that non encrypted wireless keys will not function. After all, the only message showing is the check 100. hi if i may but in the check 100 may be from (6150rf) 1. the keypad is not on it's back plate right you must hear a snap when you put the keypad on the back plate 2. or a bad keypad The OP enrolled the keyfob into the wireless key function built into the keypad, not into the wireless receiver, proper. If a 5800 series wireless receiver does not receive a transmission from a supervised transmitter within 12 hours, you get a check 100. They need to either enroll a device into the receiver via *56 programming, or turn off the receiver via the keypad programming.








Related Posts:




  • Reset ademco vista 10p

    Reset ADEMCO vista 10PI moved into a house with an ademco vista 10P alarm system and do not have any codes. How can I go about resetting? I tried the installer code with no luck. Power the system...


  • Resetting alarm keypad ademco 6150

    Resetting alarm keypad - Ademco 6150Boy this is a great forum. It seems we all manage to get ourselves in some sort of a pickle - it sure is great to have a place to find some help in these matter...


  • Reset honeywell lynx system to brandnew state

    Reset Honeywell Lynx system to brand-new state....I just bought a house that has a Honeywell Lynx system installed. I don't know any codes, and I don't have any key fobs that go with the system. I...


  • Weilmclain indirect water heater safety valve

    Weil-McLain indirect water heater safety valveWe have a Weil-McLain indirect water heater which takes the hot water from our boiler at 180 degrees and circulates it around a tank with the domestic...


  • Wireless thermostat

    Wireless Thermostat?Hello all, new to the forum, first post, so bear with me... I checked some other posts and couldn't my find exact answer, sorry if it is already there. So I think I want a wire...