Calculating Hot water baseboard requirements
I have added a large addition to my house and need to add baseboard hot water in the new area. Does any one know of a simple way to calculate just how many feet I should be installing? Also, I'll be tapping in to the existing upper level zone, so is there any way to figure out if the one zone will be adequate, or should I add another zone? Might try http://www.slantfin.com they have it all Thanks, it looks like they have the software I need... so I'll try it when I get to the coffee shop where there's wireless highspeed for my download. Yes. The simple (and, thankfully, correct) way to figure out how much baseboard you need is to go to http://www.slantfin.com/heat-loss-software-get.html and download their free heat loss software. Enter in the dimensions of the addition, number of windows, how much insulation, outdoor coldest temperature (aka design temperature) you experience each year, etc. and you will get the heat loss in BTU/hr. The program also gives you the number of feet of baseboard element required for several of their popular baseboard models. Or if you don't buy slantfin baseboard, the BTU/hr numbers can help you size another brand. As for tapping into an existing zone, it matters how long the existing zone is, how much baseboard there is on it already, what the pipe size is, how long the addition piping will be, and how much baseboard the addition will add to that zone. There's a bit of slightly advanced reading at http://www.taco-hvac.com/uploads/Fil...irculators.pdf that provides an introduction to the kinds of calculations you should do to figure things out. Several regulars here have a very good handle on this issue if you need help. That said, most residential systems are overpumped and under the max radiation per zone, so you may be able to just hack in there and go. However, it's usually worth it to scope things out beforehand so you don't have to backtrack or redo piping. I always like to recommend this one. Zoning Made Easy There's tons of good info for designers in there. Can't believe I never saw that. Clearly the hand of Holohan in that one. Great read!
Related Posts:
Baseboard hot water heater covers
baseboard hot water heater coversI am painting the interior of an old house, and the baseboard heater covers are in bad shape -- dented, badly painted, ill-fitting -- so I would like to replace th...
Baseboard heat help needed
Baseboard heat help neededI'm adding a zone to heat a room over my garage. 16' X 24' with 9' ceilings. I have room on one wall for the baseboard heat (hot water). The rest of the house has Haydon...
Do sunrad cast iron radiator work well with hot water system
Do sunrad cast iron radiator work well with hot water system?I want to have my current heat system which is heat elements replace with sunrad cast iron. I have heard that they work well with steam...
Circulating pump on water boiler furnace
circulating pump on water boiler furnace???I have a boiler fuel oil furnace that heats 1000 sq feet house it dosnt seem to heat like it should. I bled every bleeder valve. now I am wondering if I...
Cast iron baseboard radiator cover help
Cast Iron Baseboard Radiator Cover help!My wife and I recently purchased our new house an it is heated by mostly cast iron baseboard radiators (see attached photos). My wife absolutely hates the l...